ISSN 1507-2711
JOURNAL DOI: dx.doi.org/10.17531/ein
Our IF is 1.145
JCR Journal Profile


Członek(Member of): Europejskiej Federacji Narodowych Towarzystw Eksploatacyjnych  - European Federation of National Maintenance Societies  Wydawca(Publisher):Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne (Warszawa) - Polish Maintenance Society (Warsaw)   Patronat Naukowy(Scientific supervision): Polska Akademia Nauk o/Lublin  - Polish Akademy of Sciences Branch in Lublin  Członek(Member of): Europejskiej Federacji Narodowych Towarzystw Eksploatacyjnych  - European Federation of National Maintenance Societies

 


Publisher:
Polish Maintenance Society
(Warsaw)

Scientific supervision:
Polish Academy of Sciences Branch in Lublin

Member of:
European Federation
of National Maintenance Societies


Attention!

In accordance with the requirements of citation databases, proper citation of publications appearing in our Quarterly should include the full name of the journal in Polish and English without Polish diacritical marks, i.e. "Eksploatacja i Niezawodnosc – Maintenance and Reliability".


 

Submission On-Line

 




 

Impact Factor

Impact Factor

Impact Factor

Impact Factor

SCImago Journal & Country Rank

MOST CITED

Update: 2017-11-16

1. ON APPROACHES FOR NON-DIRECT DETERMINATION OF SYSTEM DETERIORATION
By: Valis, David; Koucky, Miroslav; Zak, Libor

EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY
Issue: 1   Pages: 33-41   Published: 2012

Times Cited: 40
2. UTILIZATION OF DIFFUSION PROCESSES AND FUZZY LOGIC FOR VULNERABILITY ASSESSMENT
By: Valis, David; Pietrucha-Urbanik, Katarzyna

EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY
Volume: 16   Issue: 1   Pages: 48-55   Published: 2014

Times Cited: 28
3. SELECTED ASPECTS OF PHYSICAL STRUCTURES VULNERABILITY - STATE-OF-THE-ART
By: Valis, David; Vintr, Zdenek; Malach, Jindrich

EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY
Issue: 3 Pages: 189-194 Published: 2012

Times Cited: 26
4. PREDICTING THE TOOL LIFE IN THE DRY MACHINING OF DUPLEX STAINLESS STEEL
By: Krolczyk, Grzegorz; Gajek, Maksymilian; Legutko, Stanislaw

EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY
Volume: 15 Issue: 1 Pages: 62-65 Published: 2013

Times Cited: 24
5. RELIABILITY BASED OPTIMAL PREVENTIVE MAINTENANCE POLICY OF SERIES-PARALLEL SYSTEMS
By: Peng Wei; Huang Hong-Zhong; Zhang Xiaoling; et al.

EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY
Issue: 2 Pages: 4-7 Published: 2009

Times Cited: 23
6. MAINTENANCE DECISION MAKING BASED ON DIFFERENT TYPES OF DATA FUSION
By: Galar, Diego; Gustafson, Anna; Tormos, Bernardo; et al.
EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY 
Issue: 2   Pages: 135-144   Published:2012

Times Cited: 22
7. MODELLING OF PASSIVE VIBRATION DAMPING USING PIEZOELECTRIC TRANSDUCERS - THE MATHEMATICAL MODEL
By: Buchacz, Andrzej; Placzek, Marek; Wrobel, Andrzej

EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY
Volume: 16   Issue: 2   Pages: 301-306   Published: 2014

Times Cited: 21
8. COMPUTER-AIDED MAINTENANCE AND RELIABILITY MANAGEMENT SYSTEMS FOR CONVEYOR BELTS
By: Mazurkiewicz, Dariusz

EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY
Volume: 16   Issue: 3   Pages: 377-382   Published: 2014

Times Cited: 21
9. A NEW FAULT TREE ANALYSIS METHOD: FUZZY DYNAMIC FAULT TREE ANALYSIS
By: Li, Yan-Feng; Huang, Hong-Zhong; Liu, Yu; et al.

EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY
Issue: 3 Pages: 208-214 Published: 2012

Times Cited: 18
10. PRODUCTIVITY AND RELIABILITY IMPROVEMENT IN TURNING INCONEL 718 ALLOY - CASE STUDY
By: Zebala, Wojciech; Slodki, Bogdan; Struzikiewicz, Grzegorz

EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY
Volume: 15   Issue: 4   Pages: 421-426   Published: 2013

Times Cited: 17
 

 

Visits since 2016.06.29:
darmowe liczniki


Zbigniew Nadolny

Thermal properties of a mixture of synthetic and natural esters in terms of their application in high voltage power transformers

The article presents research results of thermal properties of mixtures of synthetic and natural esters in terms of their application in the cooling system of a high-voltage power transformer during its operation. The investigated properties of an analysed mixture were: thermal conductivity coefficient λ, kinematic viscosity υ, density ρ, specific heat cp, and thermal expansion β. On the basis of presented research results, the authors determined the heat transfer factor α of a mixture of synthetic and natural esters. This factor defines the ability of an insulating liquid to transport heat in the transformer, thus determining its reliability. For the research the authors used the following percentage proportions of the mixture of both the esters: 100/0, 95/5, 80/20, 50/50, 20/80, 5/95, 0/100. The measurements were taken for the temperatures: 25ºC, 40ºC, 60ºC, and 80ºC.

Właściwości cieplne mieszaniny estrów syntetycznych i estrów naturalnych w aspekcie zastosowania w transformatorach dużej mocy

W artykule przedstawiono wyniki badań właściwości cieplnych mieszaniny estrów syntetycznych i estrów naturalnych, w aspekcie ich zastosowania w układzie chłodzenia transformatora wysokiego napięcia w trakcie jego eksploatacji. Badanymi właściwościami analizowanej mieszaniny były przewodność cieplna właściwa λ, lepkość kinematyczna υ, gęstość ρ, ciepło właściwe cp oraz rozszerzalność cieplna β. W oparciu o przedstawione wyniki badań określono współczynnik przejmowania ciepła α mieszaniny estrów syntetycznych i estrów naturalnych. Współczynnik ten określa zdolność cieczy elektroizolacyjnej do transportu ciepła w transformatorze, warunkując tym samym jego niezawodność. Do badań wykorzystano następujące procentowe proporcje mieszaniny obu estrów: 100/0, 95/5, 80/20, 50/50. 20/80, 5/95, 0/100. Pomiary przeprowadzono dla temperatury: 25ºC, 40ºC, 60ºC i 80ºC.

Liquid kind, temperature, moisture, and ageing as an operating parameters conditioning reliability of transformer cooling system

The article presents research results of thermal properties of insulating liquids used in power transformer cooling system. The authors analyzed the influence of such factors, as the kind of the liquid, temperature, moisture and ageing rate of the liquid on thermal properties of the liquids. The analyzed properties of the liquids were thermal conductivity coefficient λ, kinematic viscosity υ, density ρ, specific heat cp, and thermal expansion factor β. These properties determine the ability of the liquid to heat transport – heat transfer factor α – what means the properties describe reliability of power transformer cooling system. The authors calculated the factor of heat transfer by the investigated insulating liquids on the basis of measured values of thermal properties.

Rodzaj cieczy, temperatura, zawilgocenie oraz zestarzenie jako parametry eksploatacyjne warunkujące niezawodność układu chłodzenia transformatora

W artykule przedstawiono wyniki badań właściwości cieplnych cieczy elektroizolacyjnych, wykorzystywanych w układzie chłodzenia transformatora wysokiego napięcia. Dokonano analizy wpływu takich czynników jak rodzaj cieczy, temperatura, stopień jej zawilgocenia oraz zestarzenia na właściwości cieplne cieczy. Analizowanymi właściwościami cieczy były przewodność cieplna właściwa λ, lepkość kinematyczna υ, gęstość ρ, ciepło właściwe cp oraz rozszerzalność cieplna β. Właściwości te określają zdolność cieczy do transportu ciepła – współczynnik przejmowania ciepła α, a tym samym warunkują niezawodność układu chłodzenia transformatora. Na podstawie zmierzonych przez autorów wartości właściwości cieplnych określony został współczynnik przejmowania ciepła badanych cieczy elektroizolacyjnych.